China Good quality Gfc-80X114 Manufacturer Flexible Clamp Style Shaft Spider Gear Motor Jaw Coupling

Product Description

GFC-80X114 Manufacturer Flexible Clamp Style GFC Shaft Spider Gear Motor Jaw Coupling

 

GFC-80X114 Manufacturer Flexible Clamp Style GFC Shaft Spider Gear Motor Jaw Coupling

model parameter common bore diameter d1,d2 ΦD L LF LP F M tightening screw torque
(N.M)
GFC-14X22 3,4,5,6,6.35 14 22 14.3 6.6 5.0 M2.5 1.0
GFC-20×25 3,4,5,6,6.35,7,8,9,9.525,10 20 25 16.7 8.6 5.9 M3 1.5
GFC-20X30 3,4,5,6,6.35,7,8,9,9.525,10 20 30 19.25 8.6 5.9 M3 1.5
GFC-25X30 4,5,6,6.35,7,8,9,9.525,10,11,12 25 30 20.82 11.6 8.5 M4 2.5
GFC-25X34 4,5,6,6.35,7,8,9,9.525,10,11,12 25 34 22.82 11.6 8.5 M4 2.5
GFC-30×35 5,6,6.35,7,8,9,10,11,12,12.7,14,15,16 30 35 23 11.5 10 M4 2.5
GFC-30X40 5,6,6.35,7,8,9,10,11,12,12.7,14,15,16 30 40 25 11.5 10 M4 2.5
GFC-40X50 6,8,9,10,11,12,12.7,14,15,16,17,18,19,20,22,24 40 50 32.1 14.5 14 M5 7
GFC-40X55 6,8,9,10,11,12,12.7,14,15,16,17,18,19,20,22,24 40 55 34.5 14.5 14 M5 7
GFC-40X66 6,8,910,11,12,12.7,14,15,16,17,18,19,20,22,24 40 66 40 14.5 14 M5 7
GFC-55X49 10,11,12,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 49 32 16.1 13.5 M6 12
GFC-55X78 8,10,12,12.7,14,15,16,17,18,19,20,22,24,25,28,30,32 55 78 46.4 16.1 19 M6 12
GFC-65X80 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38,40 65 80 48.5 17.3 14 M8 20
GFC-65X90 14,15,16,17,18,19,20,22,24,25,28,30,32,35,38,40 65 90 53.5 17.3 22.5 M8 20
GFC-80X114 19,20,22,24,25,28,30,32,35,38,40,42,45 80 114 68 22.5 16 M8 20
GFC-95X126 19,20,22,24,25,28,30,32,35,38,40,42,45,50,55 95 126 74.5 24 18 M10 30

model parameter Rated torque
(N.M)*
allowable eccentricity
(mm)*
allowable deflection angle
(°)*
allowable axial deviation
(mm)*
maximum speed
rpm
static torsional stiffness
(N.M/rad)
moment of inertia
(Kg.M2)
Material of shaft sleeve Material of shrapnel surface treatment weight
(g)
GFC-14X22 5.0 0.1 1 ±02 10000 50 1.0×10-6 High strength aluminum alloy Polyurethane imported from Germany Anodizing treatment 10
GFC-20X25 5.0 0.1 1 ±02 10000 50 1.0×10-6 15
GFC-20X30 5.0 0.1 1 ^02 10000 53 1.1×10-6 19
GFC-25X30 10 0.1 1   10000 90 5.2X10-6 33
GFC-25X34 10 0.1 1 £)2 10000 90 5.2×10-6 42
GFC-30X35 12.5 0.1 1 ±02 10000 123 6.2×10-6 50
GFC-30×40 12.5 0.1 1 102 10000 123 6.2×10-6 60
GFC-40X50 17 0.1 1   8000 1100 3.8×10-5 115
GFC-40X55 17 0.1 1 ±02 8000 1100 3.8×10-5 127
GFC-40X66 17 0.1 1   7000 1140 3.9×10-5 154
GFC-55X49 45 0.1 1 ±02 6500 2350 1.6×10-3 241
GFC-55X78 45 0.1 1 102 6000 2500 1.6×10-3 341
GFC-65X80 108 0.1 1 ±02 5500 4500 3.8×10-3 433
GFC-65X90 108 0.1 1 ±02 5500 4800 3.8×10-3 583
GFC-80X114 145 0.1 1 £)2 4500 5000 1.8×10-3 1650
GFC-95X126 250 0.1 1 ±02 4000 5000 2.0×10-3 1000

 

 

 

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

spider coupling

What are the common challenges associated with spider coupling misalignment and how can they be addressed?

Misalignment is a common challenge in spider couplings that can lead to reduced efficiency, increased wear, and potential coupling failure. Here are the common challenges associated with misalignment and how they can be addressed:

  • Reduced Torque Transmission: Misalignment can decrease the effective torque transmitted between the shafts, leading to inefficiency and potential overload. Regularly check and align the shafts according to the manufacturer’s recommendations to ensure proper torque transmission.
  • Vibration and Noise: Misalignment can cause excessive vibrations and noise in the machinery. Implement precision alignment techniques during installation to minimize misalignment-induced vibrations and noise.
  • Increased Wear: Misalignment results in uneven loading on the elastomeric spider, causing premature wear and potential failure. Regularly inspect the coupling for signs of wear and replace the elastomeric spider if necessary. Address misalignment promptly to prevent excessive wear.
  • Heat Generation: Misalignment can generate heat due to friction between the elastomeric spider and the hubs. This can lead to accelerated wear and reduced coupling lifespan. Proper alignment helps minimize heat generation and associated issues.
  • Shaft Fatigue: Severe misalignment can induce shaft fatigue and stress concentrations, leading to shaft failure over time. Avoid excessive misalignment and ensure that the coupling is properly aligned during installation.
  • Reduced Service Life: Misalignment puts additional stress on the elastomeric spider, reducing its service life. Proper alignment and maintenance practices can extend the service life of the coupling.
  • Performance Variations: Misalignment can lead to variations in performance and inconsistent operation of the machinery. Regularly monitor the coupling’s performance and address any issues promptly to ensure consistent operation.

To address these challenges, it’s crucial to prioritize precision alignment during the installation of the spider coupling. Follow the manufacturer’s guidelines for alignment tolerances and use alignment tools and techniques to achieve accurate alignment. Regular maintenance, including inspections and alignment checks, will help mitigate the negative effects of misalignment and ensure the reliable performance of spider couplings in industrial applications.

spider coupling

What are the symptoms of spider coupling wear or deterioration, and how can they be identified?

Spider couplings, like other mechanical components, can experience wear and deterioration over time due to factors such as torque, misalignment, and environmental conditions. Identifying the symptoms of wear is crucial for maintaining coupling performance and preventing unexpected failures. Here are some common symptoms of spider coupling wear and deterioration:

  • Vibration and Noise: Increased vibration or unusual noise during operation can indicate wear in the spider coupling. Excessive wear can lead to reduced dampening of vibrations and increased noise levels.
  • Reduced Torque Transmission: If the coupling is no longer transmitting torque efficiently, it may indicate wear or damage to the elastomeric spider. Reduced torque transmission can result in decreased equipment performance.
  • Visible Cracks or Tears: Inspect the elastomeric spider for visible cracks, tears, or signs of deformation. These issues can lead to uneven load distribution and compromised coupling function.
  • Uneven Shaft Movement: Misalignment caused by wear can lead to uneven movement of connected shafts. This can be observed through irregular motion or wobbling during operation.
  • Increased Heat Generation: If the coupling is generating more heat than usual, it may indicate excessive friction due to wear. Overheating can accelerate wear and affect coupling performance.
  • Irregular Performance: If machinery or equipment connected by the coupling experiences irregular or unpredictable behavior, it could be a sign of coupling wear affecting torque transmission.

To identify these symptoms, regular visual inspections, vibration analysis, and performance monitoring are recommended. If any of these symptoms are observed, it’s advisable to replace the worn or damaged spider coupling with a new one. Routine maintenance and timely replacement can help ensure the continued reliability and performance of spider couplings in mechanical systems.

spider coupling

What factors should be considered when selecting a spider coupling for a specific application?

Choosing the right spider coupling for a specific application requires careful consideration of various factors to ensure optimal performance and reliability. Here are the key factors to consider:

  • Torque Requirements: Determine the torque that the coupling needs to transmit between the shafts. Select a spider coupling that can handle the required torque without exceeding its limitations.
  • Misalignment Compensation: Assess the type and degree of misalignment that the coupling needs to accommodate. Different spider coupling designs offer varying levels of misalignment compensation.
  • Operating Conditions: Consider the operating environment, including temperature, humidity, and exposure to chemicals or contaminants. Choose a spider coupling with elastomeric material that can withstand these conditions.
  • Shaft Diameters: Measure the diameters of the connected shafts. Ensure that the selected spider coupling matches the shaft sizes to achieve a secure and reliable fit.
  • Space Limitations: Evaluate the available space for installing the coupling. Choose a compact spider coupling design that fits within the available dimensions.
  • Shaft Speed: Determine the rotational speed of the shafts. Ensure that the selected spider coupling can handle the speed range without causing excessive wear or vibrations.
  • Vibration Dampening: If vibration reduction is a priority, select a spider coupling with elastomeric material that offers effective vibration dampening properties.
  • Electrical Isolation: In applications where electrical isolation is necessary, choose a spider coupling with electrically insulating properties to prevent current transmission between shafts.
  • Chemical Compatibility: If the machinery operates with specific chemicals or fluids, ensure that the elastomeric material of the coupling is compatible with these substances.
  • Cost Consideration: Evaluate the budget available for the coupling. Consider both the upfront cost and the potential savings from reduced maintenance and downtime.
  • Manufacturer Reputation: Choose spider couplings from reputable manufacturers known for producing high-quality and reliable products.
  • Application Type: Different industries and applications have unique requirements. Consider the specific demands of the application, such as pumps, compressors, conveyors, etc.

By carefully evaluating these factors, you can select a spider coupling that best matches the requirements of your application, ensuring efficient power transmission, misalignment compensation, and overall system performance.

China Good quality Gfc-80X114 Manufacturer Flexible Clamp Style Shaft Spider Gear Motor Jaw Coupling  China Good quality Gfc-80X114 Manufacturer Flexible Clamp Style Shaft Spider Gear Motor Jaw Coupling
editor by CX 2024-05-17

Comments

Leave a Reply

Your email address will not be published. Required fields are marked *