China high quality Jaw Flexible Coupling Customized Sg7-11 Zero Backlash for CNC Motors Spider Shaft Couplings

Product Description

1111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111

Item No. φD L L1 W M Tighten the strength(N.m)
SG7-11-30- 30 50 18.5 13 M3(4) 1.2
SG7-11-40- 40 66 25 16 M4(6) 2.7
SG7-11-55- 55 78 30 18 M5(4) 6
SG7-11-65- 65 90 35 20 M5(6) 6
SG7-11-80- 80 114 45 24 M6(8) 10
SG7-11-95- 95 126 50 26 M8(4) 35
SG7-11-105- 105 140 56 28 M8(4) 35

111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111

Item No. Rated torque Maximum Torque Max Speed Inertia Moment N.m rad Tilting Tolerance End-play Weight:(g)
SG7-11-30- 7.4N.m 14.8N.m 20000prm 8.7×10-4kg.m² 510N.m/rad 1.0c +0.6mm 50
SG7-11-40- 9.5N.m 19N.m 15000prm 1.12×10-3kg.m² 550N.m/rad 1.0c +0.8mm 120
SG7-11-55- 34N.m 68N.m 13000prm 4.5×10-3kg.m² 1510N.m/rad 1.0c +0.8mm 280
SG7-11-65- 95N.m 190N.m 10500prm 9.1×10-3kg.m² 2800N.m/rad 1.0c +0.8mm 450
SG7-11-80- 135N.m 270N.m 8600prm 1.9×10-2kg.m² 3600N.m/rad 1.0c +1.0mm 960
SG7-11-95- 230N.m 460N.m 7500prm 2.2×10-2kg.m² 4700N.m/rad 1.0c +1.0mm 2310
SG7-11-105- 380N.m 760N.m 6000prm 3.3×10-2kg.m² 5800N.m/rad 1.0c +1.0mm 3090

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

spider coupling

What are the common challenges associated with spider coupling misalignment and how can they be addressed?

Misalignment is a common challenge in spider couplings that can lead to reduced efficiency, increased wear, and potential coupling failure. Here are the common challenges associated with misalignment and how they can be addressed:

  • Reduced Torque Transmission: Misalignment can decrease the effective torque transmitted between the shafts, leading to inefficiency and potential overload. Regularly check and align the shafts according to the manufacturer’s recommendations to ensure proper torque transmission.
  • Vibration and Noise: Misalignment can cause excessive vibrations and noise in the machinery. Implement precision alignment techniques during installation to minimize misalignment-induced vibrations and noise.
  • Increased Wear: Misalignment results in uneven loading on the elastomeric spider, causing premature wear and potential failure. Regularly inspect the coupling for signs of wear and replace the elastomeric spider if necessary. Address misalignment promptly to prevent excessive wear.
  • Heat Generation: Misalignment can generate heat due to friction between the elastomeric spider and the hubs. This can lead to accelerated wear and reduced coupling lifespan. Proper alignment helps minimize heat generation and associated issues.
  • Shaft Fatigue: Severe misalignment can induce shaft fatigue and stress concentrations, leading to shaft failure over time. Avoid excessive misalignment and ensure that the coupling is properly aligned during installation.
  • Reduced Service Life: Misalignment puts additional stress on the elastomeric spider, reducing its service life. Proper alignment and maintenance practices can extend the service life of the coupling.
  • Performance Variations: Misalignment can lead to variations in performance and inconsistent operation of the machinery. Regularly monitor the coupling’s performance and address any issues promptly to ensure consistent operation.

To address these challenges, it’s crucial to prioritize precision alignment during the installation of the spider coupling. Follow the manufacturer’s guidelines for alignment tolerances and use alignment tools and techniques to achieve accurate alignment. Regular maintenance, including inspections and alignment checks, will help mitigate the negative effects of misalignment and ensure the reliable performance of spider couplings in industrial applications.

spider coupling

What are the symptoms of spider coupling wear or deterioration, and how can they be identified?

Spider couplings, like other mechanical components, can experience wear and deterioration over time due to factors such as torque, misalignment, and environmental conditions. Identifying the symptoms of wear is crucial for maintaining coupling performance and preventing unexpected failures. Here are some common symptoms of spider coupling wear and deterioration:

  • Vibration and Noise: Increased vibration or unusual noise during operation can indicate wear in the spider coupling. Excessive wear can lead to reduced dampening of vibrations and increased noise levels.
  • Reduced Torque Transmission: If the coupling is no longer transmitting torque efficiently, it may indicate wear or damage to the elastomeric spider. Reduced torque transmission can result in decreased equipment performance.
  • Visible Cracks or Tears: Inspect the elastomeric spider for visible cracks, tears, or signs of deformation. These issues can lead to uneven load distribution and compromised coupling function.
  • Uneven Shaft Movement: Misalignment caused by wear can lead to uneven movement of connected shafts. This can be observed through irregular motion or wobbling during operation.
  • Increased Heat Generation: If the coupling is generating more heat than usual, it may indicate excessive friction due to wear. Overheating can accelerate wear and affect coupling performance.
  • Irregular Performance: If machinery or equipment connected by the coupling experiences irregular or unpredictable behavior, it could be a sign of coupling wear affecting torque transmission.

To identify these symptoms, regular visual inspections, vibration analysis, and performance monitoring are recommended. If any of these symptoms are observed, it’s advisable to replace the worn or damaged spider coupling with a new one. Routine maintenance and timely replacement can help ensure the continued reliability and performance of spider couplings in mechanical systems.

spider coupling

How do you properly install and maintain a spider coupling in machinery?

Installation:

Proper installation of a spider coupling is essential to ensure its optimal performance and longevity. Here are the steps for installing a spider coupling:

  1. Ensure Safety: Before starting any installation, make sure the machinery is properly shut down and all energy sources are disconnected.
  2. Inspect Components: Check the hubs, elastomeric spider, and shafts for any damage or debris. Ensure that the components match the correct specifications.
  3. Align Shafts: Align the shafts to minimize initial misalignment before inserting the elastomeric spider.
  4. Insert Spider: Place the elastomeric spider into one of the hubs, ensuring that the lobes or fins are correctly aligned with the grooves in the hub.
  5. Align Second Hub: Carefully align the second hub with the first one, making sure the spider lobes fit into the grooves of both hubs.
  6. Press Hubs Together: Gently press the hubs together until they meet. Avoid using excessive force, as this could damage the elastomeric spider.
  7. Check Alignment: After installation, check the alignment of the shafts and the coupling. Misalignment should not exceed the manufacturer’s recommended limits.
  8. Tighten Fasteners: Tighten the fasteners on the hubs according to the manufacturer’s torque specifications. Use a torque wrench to ensure proper tightening.
  9. Verify Clearance: Check for proper clearance between the coupling and surrounding components to prevent interference during operation.
  10. Run System: Start the machinery and monitor the coupling for any unusual vibrations or noise. Make any necessary adjustments if issues are detected.

Maintenance:

Maintaining a spider coupling is important to ensure its continued performance and prevent premature failure. Here are some maintenance tips:

  • Regular Inspection: Periodically inspect the spider coupling for signs of wear, damage, or deterioration. Look for cracks, tears, or other abnormalities in the elastomeric spider.
  • Clean Environment: Keep the coupling and surrounding area clean from dirt, debris, and contaminants that could impact its performance.
  • Lubrication: Spider couplings are self-lubricating due to the elastomeric material. Avoid using additional lubricants, as they can deteriorate the elastomeric properties.
  • Temperature Consideration: Be aware of the temperature range specified by the manufacturer for the elastomeric material. Extreme temperatures can affect the performance and lifespan of the coupling.
  • Replace Worn Parts: If the elastomeric spider shows signs of wear, replace it with a new one from the manufacturer. Do not continue using a worn or damaged spider.
  • Monitor Vibrations: Regularly monitor the machinery for unusual vibrations or noise, as these can indicate issues with the coupling. Address any problems promptly.
  • Follow Manufacturer Guidelines: Adhere to the manufacturer’s recommended maintenance schedule and guidelines for the specific spider coupling model.

Proper installation and regular maintenance contribute to the reliable and efficient operation of a spider coupling in machinery.

China high quality Jaw Flexible Coupling Customized Sg7-11 Zero Backlash for CNC Motors Spider Shaft Couplings  China high quality Jaw Flexible Coupling Customized Sg7-11 Zero Backlash for CNC Motors Spider Shaft Couplings
editor by CX 2024-04-11